Distribution also available via Siemens Medical Solutions |
FSS SCHEDULE NUMBER
V797P-3222M
|
SAFESCAN® INTERCEPT PILLAR® (Dual Pillar System)
- Establishes the benchmark as the premiere and most cost-effective dual pass-through ferromagnetic detector in the marketplace
- Utilizes non-radiating, completely passive DC field to increase sensitivity - proprietary patented feature which does NOT affect imaging quality or patient safety (no magnetic pulses of any kind; no need for shielding)
- Freestanding or mounted versions, depending on site layout requirements
- Unsurpassed flexibility - wide for doorway, or narrow for more sensitive subject screening
- 4 sensitivity settings allow accommodation to your particular environment
- The use of gradiometers to significantly reduce objectionable false alarms
- Variable-volume 2-tone audible alarm, and large LED lights atop each pillar easily visible from all sides
- Night-light mode and sensitivity lock for after hours MR Safety protection
- Ideally suited for use with our hand-held SAFESCAN® TARGET SCANNER™
- Mednovus Quality, Durability, and 3-Year Warranty
- Total Commitment to our Customers – We go the extra mile for you!
Set at a narrower configuration (26-33 inches), the SAFESCAN INTERCEPT PILLAR ferromagnetic detector has greater sensitivity for smaller ferromagnetic threats. The SAFESCAN INTERCEPT PILLAR system is positioned up to 54 inches apart (or greater when required) to provide doorway protection for larger threats, either entering Zone III or within Zone III protecting the magnet room door (frequently 48 inches wide).
Note: If small ferromagnetic threat objects pass through the aperture closely to the sensors located in each pillar's vertical limb, these can often be detected, even if the pillars are spaced at a wider distance. With ANY ferromagnetic detection ferromagnetic detector sensitivity increases to the cube of the distance - 2x closer to the sensors results in 8x increase sensitivity.
The SAFESCAN INTERCEPT PILLAR ferromagnetic detector system has a fundamental (patented) technological advantage because of the utilization of a non-radiating, passive (DC) magnetic field to improve sensitivity and detection capability. This is especially important for detection of non-premagnetized ferromagnetic objects which have no magnetic moment of their own.
We emphasize that the independent field of our SAFESCAN® products, including the SAFESCAN INTERCEPT PILLAR system, is completely passive (i.e., DC) and there is NO electromagnetic radiation and no pulsed magnetic fields. Imaging quality will not be affected in any way, nor will credit cards be erased, and no shielding is required. Cell phones are unaffected.
The SAFESCAN INTERCEPT PILLAR ferromagnetic detector system can be used with pacemakers for medically cleared patients. (However, most centers do not scan patients with pacemakers in the first place.) The field diminishes to less than 5 gauss at a distance of 2 feet.
Since the SAFESCAN INTERCEPT PILLAR ferromagnetic detector system operates completely independently of the MRI fringing field, it can be positioned where it makes the most sense, a siting advantage. And because each pillar weighs less than 40 pounds, it takes only a few moments to reposition or reconfigure the pillars, wider, narrower, or to a completely new location.
The components of the SAFESCAN INTERCEPT PILLAR ferromagnetic detector system are of the highest quality to maximize signal-to-noise ratio, detectability, and durability. The SAFESCAN INTERCEPT PILLAR ferromagnetic detector system is frequently used in tandem with the hand-held SAFESCAN TARGET SCANNER™.
The SAFESCAN INTERCEPT PILLAR ferromagnetic detector system is properly used as a double-check safety precaution AFTER the patient has been medically cleared to enter the magnet room.
Conforms to ACR, Joint Commission,
and VA best-practice guidance documents
For more information:
Tobias (Toby) Gilk, President & MRI Safety Director
at tobias.gilk@mednovus.com or 913.515.8449 (Central Time)
Kemp Massengill, CEO & Quality Assurance Director
at kemp.massengill@mednovus.com or 760.390.1410 (Pacific Time)
We help protect your patients...
your magnet... and your investment™
Ferromagnetic detection is intended to supplement - but NOT to replace conscientious medical screening protocols.
|
For additional SAFESCAN® products
please click here
|